VIEWSONIC N1900W-1E  SERVICE MODE FIRMWARE UPDATE AND POWER SUPPLY CIRCUIT 

ADJUSTMENT CONDITIONS AND PRECAUTIONS
1. Approximately 30 minutes should be allowed for warm up before proceeding.
2. Adjustments should be undertaken only on those necessary elements since most of them have been carefully preset at the factory.
3. ESD protection is needed before adjustment.
2. MAIN ADJUSTMENTS
NO. FUNCTION DESIGNATION
1. PC AUTO COLOR Function Key
2. Adjust color temperature Function Key
3. ALIGNMENT PROCEDURES
Adjustment Conditions and Precautions:
(A). Power supply voltage:
AC 220/240V± 10% 50 Hz ± 5%.
(B). Warm up time:
The display must be power ON for at least 30 minutes at full white pattern before starting alignments.
This is especially critical in color temperature and white balance adjustments.
(C). Video : reference the front detail specifications.
I. EEPROM INIT (Factory mode )
(A). Power OFF(LED Orange), then Press “UP”+“ENTER” and “POWER” key, When Power on , Press “MENU” key go to factory mode.

B). Press “ ENTER” key to do EEPROM INIT.
C).When EEPROM INIT finish the above information OSD will disappear.
II. PC AUTO COLOR:
A) Move the color bar to “WHITE BALANCE”, then press “ ENTER” key to Adjust color temperature Set at PC Souce timing set at 1440x900 60HZ
Use Chroma 2327 pattern Generator PATTEN use 5 block

B).When the Adjust color temperature finish, the OSD will move to “OFFSET” automatic.
Then check color temperature value:
X=0.313±0.03
Y=0.329±0.03
Y=230(min)
Preset (6500K)
Press “ MENU” key to exit .
Press “ POWER” key quit factory mode
4. Firmware Upgrade Procedure
When you receive the returned LCD TV, please check whether the firmware version is the latest. If not, please do the following procedures to upgrade it to the latest version.
1. Prepare N1900W(E) ISP Board in hand first.

2. Plug in the ISP Board into your PC Printer Port, then switch the PC on to stand by.

Install Printer Port Driver, and then install Setup_LptDrv_v020201_XP_2000. After installation is completed, make sure you restart the PC.

3. Light up the LCD TV monitor, and then plug the 4Pin female component into the 4Pin male component under the rear cover of the LCD TV. (Note that the LCD TV monitor must be lighted on now)

4. Run the .exe file under the path of C:\Program\Micronas\LptDrv\LptDrvTest from your PC. If the following screen appears, then the ISP Printer Port Device is functioning normally.

5. Install ISP I2C Driver, and then install the installation program of
Setup_Visual_i2c_v3-2-3b8h.exe. After installation is completed, you can see the .exe file under 
Windows O.S.C::\program\micronas\visual I2C program.
6. After the ISP I2C is installed, you can run the C:\VCTI\vct49xyi_start.vi2c.exe program under VCTI menu.
7. When the above screen shows, the TVT Item is running, and the following screen will appear.

8. When the above picture appears, click on the Bootloader Item with your mouse cursor, and the following screen will appear. Keep running the Bootloader Item until the LCD TV screen disappears all at once, and then you can enter ISP Mode.
9. Run Bootloader Version again. Press the Enter key continuously, and the Version 22 screen will appear.
10. Run the Erase Flash commander again, and run the Load Bin->Flash commander, and then choose the location of Load Bin File as follows.
11. When the following screen appears, the program is being burend-in (about 2.5 min), and the program is updated.
When you receive the returned monitor, please check whether the firmware version is the latest. If not, please do the following procedures to upgrade it to the latest version.

POWER SUPPLY CIRCUIT 
CLICK ON THE IMAGE TO ZOOM IN