Description
This error monitored the rotating
speed of an external cooling fan attached to the drive motor on
9.55, C954 version 1 and C956
version 1 treadmills. The system used an optical speed sensor
that read an infrared signal
reflected back to the speed sensor from a target attached to the hub
of the cooling fan.
Possible
Causes
1. It was determined that the fan
speed sensing system was unreliable and false error 13
indications were being displayed.
The lower software was changed to remove all error 13
indications.
2. If the installed software
includes an error 13, the fan may be clogged with dust and/or dirt.
Possible
Remedies
1. Replace the lower PCA software
with the most current lower PCA software available.
2. Clean the fan. If the error 13
still occurs, replace the lower PCA software with the most
current
lower PCA software available.