SYLVANIA LC370SS8 SERVICE MODE RESETTING AND POWER SUPPLY CIRCUIT

SYLVANIA BLU RAY

SYLVANIA LC370SS8

LCD TV


SERVICE MODE RESETTING  AND POWER SUPPLY CIRCUIT  

How to initialize the LCD television:
1. Turn the power on.
2. To enter the service mode, press the service button on the service remote control unit
- To cancel the service mode, press [POWER] button on the remote control unit.
3. Press [INFO] button on the remote control unit to initialize the LCD television.
4. "INITIALIZED" will appear in the upper right of the screen. "INITIALIZED" color will change to green from red when initializing is complete.
SERVICE MODE
1. Use the service remote control unit.
2. Turn the power on.
3. Press the service button on the service remote control unit.
How to make the Service remote control unit:
Cut “A” portion of the attached remote control unit as shown in Fig.


Purity Check Mode
This mode cycles through full-screen displays of red, green, blue, and white to check for non-active pixels.
1. Enter the Service mode.
2. Each time pressing [7] button on the service remote control unit.
VCOM Adjustment
*This adjustment is required when reparing T-CON CBA.
1. Operate the unit for more than 20 minutes.
2. Set the color analyzer and bring the optical receptor to the center on the LCD-Panel surface after zero point calibration as shown above.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
3. Enter the Service mode.
4. Press [3] button on the remote control unit.
5. Press [CH UP / DOWN] buttons on the remote control unit so that the color analyzer value becomes minimum.
White Balance Adjustment
*This adjustment is required when reparing T-CON CBA.
Purpose: To mix red, green and blue beams correctly for pure white.
Symptom of Misadjustment: White becomes bluish or reddish.
1. Operate the unit for more than 20 minutes.
2. Input the White Purity
3. Set the color analyzer to the CHROMA mode and bring the optical receptor to the center on the LCD-Panel surface after zero point calibration as shown above.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
4. Enter the Service mode. Press [VOL. DOWN] button on the remote control unit and select “C/D” mode.
5. [CUTOFF]
Press [3] button to select “COB” for Blue Cutoff adjustment. Press [1] button to select “COR” for Red Cutoff adjustment.
[DRIVE]
Press [6] button to select “DB” for Blue Drive adjustment. Press [4] button to select “DR” for Red Drive adjustment.
6. In each color mode, press [CH UP / DOWN] buttons to adjust the values of color.
7. Adjust Cutoff and Drive so that the color temperature becomes 12000K (x= 0.272 / y= 0.278 ±0.005).
POWER SUPPLY CIRCUIT 
CLICK ON THE IMAGE TO ZOOM IN

BACK LIGHT INVERTER CIRCUIT 
CLICK ON THE IMAGE TO ZOOM IN