SAMSUNG HPT 4264X, HTP5064X SERVICE MODE

SAMSUNG HPT 4264X, HTP5064X

 SERVICE MODE 

How to Access Service Mode

1. General Remote
To Enter

POWER OFF > MUTE > 1 > 8 >  2  > POWER ON 
(Interval between key strokes: less than 3 sec)
To Exit:
POWER OFF > POWER ON

2. Factory Remote
To Enter:
 POWER ON >  INFO >FACTORY Key (Interval between key strokes: less than 3 sec)
To Exit:
POWER OFF > POWER ON
Press the Factory key twice with a key stroke interval of more than 1 second (Pressing once enters Aging Mode)
3. Settings when entering Factory mode
- Sharp Screen (Dynamic), Color Tone (Cool1), Factory (Dynamic CE Off), DNIe(Off)
4. Adjustment Procedures
- Channel
Key : Select an item.
- Volume <
> Key : Adjust the value up or down.
- MENU Key : Save the changes to the EEPROM and return to the higher-level mode.
- Using the Numeric (0~9) keys, you can select a channel.
- Using the SOURCE key, you can switch AV modes.

Method of Color Calibration (AV)
1) Apply the NTSC Lattice (N0. 3) pattern signal to the AV IN 1 port
2) Press the Source key to switch to "AV1" mode
3) Enter Service mode
4) Select the "Calibration" menu
5) Select the "AV Calibration" menu.
6) In "AV Calibration Off" status, press the "
" key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the "AV Calibration" status from Failure to Success.
Method of Color Calibration (Component)
1) Apply the 720p Lattice (N0. 6) pattern signal to the Component IN 1 port
2) Press the Source key to switch to "Component1" mode
3) Enter Service mode
4) Select the "Calibration" menu
5) Select the "Comp Calibration" menu.
6) In "Comp Calibration Off" status, press the "
" key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the "Comp Calibration" status from Failure to Success.
Method of Color Calibration (PC)
1) Apply the VESA XGA Lattice (N0. 21) pattern signal to the PC IN port
2) Press the Source key to switch to "PC" mode
3) Enter Service mode
4) Select the "Calibration" menu
5) Select the "PC Calibration" menu.
6) In "PC Calibration Off" status, press the "
" key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the "PC Calibration" status from Failure to Success.
 Method of Color Calibration (HDMI)
1) Apply the 720p Lattice (N0. 6) pattern signal to the HDMI1/DVI IN port
2) Press the Source key to switch to "HDMI1" mode
3) Enter Service mode
4) Select the "Calibration" menu
5) Select the "HDMI Calibration" menu.
6) In "HDMI Calibration Off" status, press the "
" key to perform Calibration.
7) When Calibration is complete, it returns to the high-level menu.
8) You can see the change of the "HDMI Calibration" status from Failure to Success.
USB Download Method
1. Copy the Upgrade Files into the path "
callaus" in USB flash driver.
2. USB Download
1 Insert the USB Memory Stick to the WISELINK port in Stand-by mode.
2 Turn the power on.
3 Press "MENU" and find "SW Upgrade" in Menu "SETUP".
4 Select the "SW Upgrade" from the menu.
5 Select "USB" from the menu.
6 The banner OSD "Scaning for USB..." is displayed.
7 The banner OSD "Upgrade version **** to version ****" is displayed. Select "Yes".
8 The banner OSD "Upgrade version **** to version ****" is displayed. It takes about 30 sec.
(Warning: Don't remove USB flash driver during upgrade.)
9 The banner OSD "Upgrade is completed" is displayed when the upgrade is completed.
10 Remove the USB flash driver from PDP TV and check the program version.