SONY KDL - 40W5500
SERVICE MODE AND POWER SUPPLY CIRCUIT
How to enter the Service Mode
Service adjustments to this model can be performed using the supplied Remote Commander RM-ED016.
1. Turn on the power to the TV set and enter into the stand-by mode.
2. Press the following sequence of buttons on the Remote Commander.
1. Turn on the power to the TV set and enter into the stand-by mode.
2. Press the following sequence of buttons on the Remote Commander.
ON SCREEN DISPLAY > CH 5 > VOLUME + > POWER ON
3. The TVM menu appears on the screen
Note : After carrying out the service adjustments, to prevent the customer accessing the ‘Service Menu’ switch the TV set OFF and then ON.
Changing TVM Data Settings
1. Press “2 / 5” on the remote commander to select (up / down) category.
2. Press “1 / 4” on the remote commander to select (up / down) item.
3. Press “3 / 6” on the remote commander to select (up / down) data .
2. Press “1 / 4” on the remote commander to select (up / down) item.
3. Press “3 / 6” on the remote commander to select (up / down) data .
Writing TVM Data
1.Press “Mute” on the remote commander. The word “SERVICE” changes to “WRITE”
2.Press “0” on the remote commander. The word “WRITE” changes to red. This indicates writing is in progess.
3. When red “WRITE” changes to green “SERVICE”. This indicates writing is complete.
ON SCREEN DISPLAY > CH 5 > VOLUME -- > POWER ON
SELF DIAGNOSTIC
SOFTWARE
The identification of
errors within the EX2L chassis is triggered in one of two ways :- 1: Busy or 2:
Device failure to respond to IIC. In the event of one of these situations
arising the software will first try to release the bus if busy (Failure to do so
will report with a continuous flashing LED) and then communicate with each
device in turn to establish if a device is faulty. If a device is found to be
faulty the relevant device number will be displayed through the LED (Series of
flashes which must be counted).
To bring up the self diagnostic screen display
LED Flashes
|
Error Description
|
Error (Comp ref)
|
02
|
main Power Error
|
Pwr_Err
|
05
|
DC_Alert3
|
DC_Alt
|
06
|
Backlight Error
|
Bck_Lgt
|
07
|
Thermal Error
|
Thm_Err
|
08
|
Audio Error
|
Aud_Err
|
10
|
Digital FE/BE Error
|
Dig_Err
|
12
|
HFr Error (T-Con)
|
Hfr_Err
|
13
|
Balancer Error
|
Bal_Err
|
14
|
T-Con Error
|
Tcn_Err
|
To bring up the self diagnostic screen display
In standby mode, press
the following buttons on the remote commander sequentially in rapid sucession
as shown below:
POWER SUPPLY CIRCUIT
CLICK ON THE IMAGE TO ZOOM IN
3 DIGIT UNIVERSAL REMOTE REMOTE CODES FOR SONY TV
006, 301, 005, 446, 412, 393, 375, 360, 325, 255, 203, 185, 174, 058, 003