EPSON STYLUS PRO 10600 ERROR CODES

EPSON STYLUS PRO 10600

ERROR CODES 

Maintenance Requests Errors
MAINTENANCE REQ ­ 0100 ­
Waste ink pads are full
MAINTENANCE REQ ­ 0101 ­
The CR motor reached the 3% remaining to the life.
MAINTENANCE REQ ­ 0102 ­
Auto nozzle check error
MAINTENANCE REQ ­ 0103 ­
Backup battery for RTC (real time clock) life expired.
MAINTENANCE REQ ­ 0104 ­
Dot missing detector error
Service Request Errors
SERVICE REQ ­ 00000100 ­
Waste ink pads are full
SERVICE REQ ­ 00000101 ­
CR motor life (Ink tubes also reached their life)
SERVICE REQ ­ 00000102 ­
Nozzle check error compulsory continuity
SERVICE REQ ­ 00000103 ­
RTC backup battery end
SERVICE REQ ­ 00000104 ­
Auto print head optimization system
SERVICE REQ ­ 00000105 ­
Head unit life end
SERVICE REQ ­ 00000106 ­
Cleaning unit life end
SERVICE REQ ­ 00010000 ­
PF motor/ encoder check error
SERVICE REQ ­ 00010001 ­
PF motor step­out
SERVICE REQ ­ 00010002 ­
PF motor/overcurrent
SERVICE REQ ­ 00010003 ­
PF motor/ in position time­out error
SERVICE REQ ­ 00010004 ­
CR motor/ encoder check error
SERVICE REQ ­ 00010005 ­
CR motor step­out
SERVICE REQ ­ 00010006 ­
CR motor/overcurrent
SERVICE REQ ­ 00010007 ­
CR motor/ in position time­out error
SERVICE REQ ­ 00010008 ­
Servo interruption watch dog time out error
SERVICE REQ ­ 00010009 ­
System interruption watch dog time out error
SERVICE REQ ­ 0001000A ­
CR origin sensor mulfanction
SERVICE REQ ­ 0001000B ­
PF origin sensor mulfanction
SERVICE REQ ­ 0001000C ­
HS origin sensor mulfanction
SERVICE REQ ­ 0001000D ­
Cover sensor mulfanction
SERVICE REQ ­ 0001000E ­
Cover sensor mulfanction
SERVICE REQ ­ 0001000F ­
CR motor over heat (PWM output malfunction)
SERVICE REQ ­ 00010010 ­
PF motor over heat (PWM output malfunction)
SERVICE REQ ­ 00010011 ­
Paper jam error
SERVICE REQ ­ 00010012 ­
Cap origin error
SERVICE REQ ­ 00010013 ­
Providing system origin error
SERVICE REQ ­ 00010014 ­
Pressurization error
SERVICE REQ ­ 00010015 ­
Liquid sensor overflow (K)
SERVICE REQ ­ 00010016 ­
Liquid sensor overflow(C)
SERVICE REQ ­ 00010017 ­
Liquid sensor overflow (M)
SERVICE REQ ­ 00010018 ­
Liquid sensor overflow (LC)
SERVICE REQ ­ 00010019 ­
Liquid sensor overflow (LM)
SERVICE REQ ­ 0001001A ­
Liquid sensor overflow (Y)
SERVICE REQ ­ 0001001B ­
Head driver (TG) temperature error
SERVICE REQ ­ 0001001C ­
FS origin (Suction fan shutter home position) error
SERVICE REQ ­ 0001001D ­
CR servo parameter error
SERVICE REQ ­ 0001001E ­
PF servo parameter error
SERVICE REQ ­ 00010020 ­
CSIC card read/write error
SERVICE REQ ­ 00010021 ­
Starter cartridge error
SERVICE REQ ­ 00010022
I­nk type NVRAM status error
SERVICE REQ ­ 00010023 ­
RTC operation malfunction
SERVICE REQ ­ 00010024 ­
Module communication time­out error
SERVICE REQ ­ 00010025 ­
CSIC EEROR access error
SERVICE REQ ­ 00010026 ­
RTC access error
SERVICE REQ ­ 00010027 ­
Pressure pump small leak error
SERVICE REQ ­ 00010028 ­
During cleaning, pressure pump small leak error
SERVICE REQ ­ 00020000 ­
NVRAM error
SERVICE REQ ­ 00020001 ­
NVRAM check sum error
SERVICE REQ ­ 00020002 ­
SDRAM error
SERVICE REQ ­ 00020003 ­
Flash memory sum error
SERVICE REQ ­ 00020004 ­
ASIC illegal version error
SERVICE REQ ­ 00020005 ­
Firmware ASIC mismatching error (Version:A)
SERVICE REQ ­ 00020006 ­
Firmware ASIC mismatching error (Version:B)
SERVICE REQ ­ 00020007 ­
Head/ASIC mismatch error
SERVICE REQ ­ 00020009 ­
Flash memory check sum error
SERVICE REQ ­ 0002000B ­
Memory insufficient error
SERVICE REQ ­ 0002000C ­
Review error
SERVICE REQ ­ 00030000 ­ 00030013 ­
Debug error
SERVICE REQ ­ 00030015 ­
Ink supply defective (K)
SERVICE REQ ­ 00030016 ­
Ink supply defective (C)
SERVICE REQ ­ 00030017 ­
Ink supply defective (M)
SERVICE REQ ­ 00030018 ­
Ink supply defective (LC)
SERVICE REQ ­ 00030019 ­
Ink supply defective (LM)
SERVICE REQ ­ 0003001A ­
Ink supply defective (Y)
SERVICE REQ ­ 0003001B ­
GAP adjustment range error
SERVICE REQ ­ 0003001C ­
Timeout in case of no print finishing with ASIC
SERVICE REQ ­ D0120013 ­
Module comminication error
SERVICE REQ ­ D012001E ­
Engine side ASIC command transmission over flow
SERVICE REQ ­ D012001F ­
Engine side ASIC command receiption over error
SERVICE REQ ­ D0xxxxxx ­
Program error
SERVICE REQ ­ 10000E0 ­
CPU address error
SERVICE REQ ­ 1000100 ­
CPU address error
SERVICE REQ ­ 10000180 ­
CPU reservation instruction code exception error
SERVICE REQ ­ 100001A0 ­
CPU Slot unfair command exception error
SERVICE REQ ­ 100005C0 ­
CPU DMA address error
SERVICE REQ ­ 10000xxx ­
CPU illegal trap
SERVICE REQ ­ FFFFxxxx ­
OS kernel detection error