EPSON STYLUS PRO GS6000 ERROR CODES AND CAUSES

EPSON STYLUS PRO GS6000 

ERROR CODES AND CAUSES 

SERVICE ERROR
SERVICE CALL ­ 1101 ­ 
Life end of the CR MOTOR
SERVICE CALL ­ 1125 ­ 
Carriage home position detection
SERVICE CALL ­ 1133 ­ 
CR MOTOR in position time­out error
SERVICE CALL ­ 1135 ­ 
CR ENC ASSY check error
SERVICE CALL ­ 1136 ­ 
CR MOTOR step­out error
SERVICE CALL ­ 1137 ­ 
CR servo parameter error
SERVICE CALL ­ 1223 ­ 
PF ENCODER ASSY check error
SERVICE CALL ­ 1225 ­ 
PF MOTOR in position time­out error
SERVICE CALL ­ 1227 ­ 
PF MOTOR step­out error
SERVICE CALL ­ 1228 ­
 PF servo parameter error
SERVICE CALL ­ 131B ­
 Head driver (transmission gate) overheat error
SERVICE CALL ­ 1700 ­ 
Print position error
SERVICE CALL ­ 1900 ­ 
HEATER CONT BOARD serial connection failure
SERVICE CALL ­ 1902 ­ 
Over Temp PRE HEATERS(64) on the HEATER RELAY
SERVICE CALL ­ 1903 ­ 
Over Temp PLATEN HEATER(64) on the HEATER RELAY
SERVICE CALL ­ 1904 ­ 
Over Temp AFTER HEATER(64) on the HEATER RELAY
SERVICE CALL ­ 1905 ­ 
Over Temp PRE HEATERS(64) on the HEATER RELAY
SERVICE CALL ­ 1906 ­
 Over Temp PLATEN HEATER(64) on the HEATER RELAY
SERVICE CALL ­ 1907 ­ 
Over Temp AFTER HEATER(64) on the HEATER RELAY
SERVICE CALL ­ 1908 ­ 
An abnormal voltage of the heater on the HEATER CONT
SERVICE CALL ­ 1909 ­ 
Comms Failure HEATER CONT BOARD and SUB­Board
SERVICE CALL ­ 1910 ­ 
Under Temp PRE HEATERS(64) on the HEATER RELAY
SERVICE CALL ­ 1911 ­ 
Under Temp PLATEN HEATER on the HEATER RELAY
SERVICE CALL ­ 1912 ­ 
Under Temp AFTER HEATER on the HEATER RELAY
SERVICE CALL ­ 1920 ­ 
HEATER CONT BOARD ­SUB TANK SENSOR 1 failure
SERVICE CALL ­ 1921 ­ 
HEATER CONT BOARD ­SUB TANK SENSOR 2 failure 
SERVICE CALL ­ 1922 ­ 
HEATER CONT BOARD ­SUB TANK SENSOR 3 failure 
SERVICE CALL ­ 1923 ­ 
HEATER CONT BOARD ­SUB TANK SENSOR 4 failure
SERVICE CALL ­ 1924 ­ 
HEATER CONT BOARD ­SUB TANK SENSOR 5 failure 
SERVICE CALL ­ 1925 ­ 
HEATER CONT BOARD ­SUB TANK SENSOR 6 failure
SERVICE CALL ­ 1926 ­ 
HEATER CONT BOARD ­SUB TANK SENSOR 7 failure
SERVICE CALL ­ 1927 ­ 
HEATER CONT BOARD ­SUB TANK SENSOR 8 failure
SERVICE CALL ­ 1A23 ­ 
RTC analysis error
SERVICE CALL ­ 1A26 ­ 
RTC communication error
SERVICE CALL ­ 1A37 ­ 
Head thermistor error
SERVICE CALL ­ 1A38 ­ 
Transistor thermistor error
SERVICE CALL ­ 1A39 ­ 
Head error
SERVICE CALL ­ 1A40 ­ 
MAIN BOARD ASSY IC2 error
SERVICE CALL ­ 1A41 ­ 
Head rank ID input error
SERVICE CALL ­ 2000 ­ 
NVRAM error
SERVICE CALL ­ 2002 ­ 
SDRAM error
SERVICE CALL ­ 2003 ­ 
Boot program sum error
SERVICE CALL ­ 200A ­ 
Program loading error
SERVICE CALL ­ 200B ­ 
Internal insufficient memory error
SERVICE CALL ­ 200C ­ 
Servo interrupt watchdog time­out error
SERVICE CALL ­ 200D ­ 
System interrupt watchdog timeout error
SERVICE CALL ­ 200E ­ 
Unknown NMI 
SERVICE CALL ­ 3000 ­  
AC power shut­off
SERVICE CALL ­ FXXX ­ 
CPU­related error
MAINTENANCE ERROR
MAINTENANCE REQ ­ 0001 ­ 
CR scan pass counter reached the specified value.
 MAINTENANCE REQ ­ 0011 ­ 
The RTC backup battery becomes exhausted.
MAINTENANCE REQ ­ 0111 ­ 
The date has not been set.
MAINTENANCE REQ ­ 0100 ­ 
The following two errors are occurring, 0001 & 0011 M
AINTENANCE REQ ­ 1000 ­ 
The following two errors are occurring, 0001 & 0011
MAINTENANCE REQ ­ 1010 ­ 
The following two errors are occurring, 0011 & 0111