PANASONIC TC-L32E5
LED LCD
SERVICE MODE LED BLINKING CODE AND POWER SUPPLY CIRCUIT
How to
enter into Service Mode
While pressing [VOLUME ( - )] button of the main unit, press [INFO] button of the remote control three times within 2 seconds.
While pressing [VOLUME ( - )] button of the main unit, press [INFO] button of the remote control three times within 2 seconds.
How to
exit
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
Switch off the power with the [POWER] button on the main unit or the [POWER] button on the remote control.
TOOL FOR
SRV
How to access
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
How to access
1. Select [SRV-TOOL] in Service Mode.
2. Press [OK] button on the remote control.
SOS
History Display
SOS History (Number of LED blinking ) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment. This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory shipment setting].
SOS History (Number of LED blinking ) indication.
From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment. This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory shipment setting].
ABOUT POWER
ON TIME/COUNT
Note : To display TIME/COUNT menu, highlight position, then press MUTE for 3sec.
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of ON times by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
Note : To display TIME/COUNT menu, highlight position, then press MUTE for 3sec.
Time : Cumulative power on time, indicated hour : minute by decimal
Count : Number of ON times by decimal
Note : This indication will not be cleared by either of the self-checks or any other command.
Exit
1. Disconnect the AC cord from wall outlet.
1. Disconnect the AC cord from wall outlet.
Self
Check Mode
1. Press the ‘MENU’ button (on the remote control) and the ‘VOL DOWN’ button on the LCD panel.
2. Press ON/OFF button on the panel to Exit.
Hotel Mode Adjustment
1. Press the ‘VOLUME DOWN’ button on the TV panel and simultaneously press the INPUT button on the remote control 3 times to enter Hotel Mode.
2. Set Hotel mode ‘on/off’, then press ‘EXIT’ to come out.
1. Press the ‘MENU’ button (on the remote control) and the ‘VOL DOWN’ button on the LCD panel.
2. Press ON/OFF button on the panel to Exit.
Hotel Mode Adjustment
1. Press the ‘VOLUME DOWN’ button on the TV panel and simultaneously press the INPUT button on the remote control 3 times to enter Hotel Mode.
2. Set Hotel mode ‘on/off’, then press ‘EXIT’ to come out.
HOW TO
ACCESS HOTEL MODE
1. Purpose
Restrict a function for hotels.
2. Access command to the Hotel mode setup menu. In order to display the Hotel mode setup menu, please enter the following command (within 2 second). [TV] : Vol [Down] + [REMOTE] : INPUT (3 times)
1. Purpose
Restrict a function for hotels.
2. Access command to the Hotel mode setup menu. In order to display the Hotel mode setup menu, please enter the following command (within 2 second). [TV] : Vol [Down] + [REMOTE] : INPUT (3 times)
3. To exit the Hotel
mode setup menu
Disconnect AC power cord from wall outlet.
Disconnect AC power cord from wall outlet.
IIC bus
lines Checking
How to
access
Self-check indication only:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control for more than 3 seconds.
Self-check indication and forced to factory shipment setting:
Self-check indication only:
Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control for more than 3 seconds.
Self-check indication and forced to factory shipment setting:
Produce TV reception
screen, and while pressing [VOLUME ( - )] button on the main unit, press [MENU]
button on the remote control for more than 3 seconds.
Exit
Disconnect the AC cord from wall outlet.
Disconnect the AC cord from wall outlet.
Power LED
Blinking
1. Subject
Information of LED Flashing timing chart.
2. Contents
When an abnormality occurs, the protection circuit will operate and reset the unit to stand by mode. During this time, the
defective block can be identified by the number of blinking times of the Power LED on the front panel of the unit as follow:
1. Subject
Information of LED Flashing timing chart.
2. Contents
When an abnormality occurs, the protection circuit will operate and reset the unit to stand by mode. During this time, the
defective block can be identified by the number of blinking times of the Power LED on the front panel of the unit as follow:
Priority
|
Name
|
Factor
|
R_LED Blink
|
1
|
BL_SOS
|
SOS from
PANEL inverter
|
1
|
2
|
POWER_SOS
|
SOS from
POWER Curcuit
|
3
|
3
|
SOUND_SOS
|
SOS from
audio AMP
|
9
|