SANYO DP55360 SERVICE MODE AND POWER SUPPLY CIRCUIT

SANYO DP55360 

SERVICE MODE AND POWER SUPPLY CIRCUIT 

ON-SCREEN SERVICE MENU SYSTEM
1. Enter the Service Menu
# Turn off the receiver and disconnect the AC power supply.
# While pressing the Volume (–) button on the television, reconnect the AC power supply. The Service Menu will now appear. The remote can now be used to make adjustments. .
2. Service Adjustments
# Press the Cursor
UP and DOWN  key to select the desired service menu item you want to adjust. See page 4 for the On-screen Service Menu.
# Use the Cursor  or  key to adjust the data. The LEFT or  RIGHT  key will increase or decrease the data sequentially.
3. Exit from the Service Menu
# Press the MENU key to turn off the Service Menu display.
PROGRAM CODES
The microprocessor used in this model is a multi-purpose type and is used in several different models. To ensure proper operation and the correct features for your particular model, the program codes must be correct.
Note 1. Option Data 1 (NO. 087 OP1) should be hexadecimal 00. See 087 above. If this program code is wrong the TV will not operate properly.
Note 2. Option Data 2 (NO. 088 OP2) should be hexadecimal 2A. See 088 above. If this program code is wrong the TV will not operate properly.
POWER FAILURE CIRCUIT
CPU (IC800) is programmed so the set will go to standby mode when there is circuit failure as described below. (Refer to“Block Diagram Power Lines”.)
This unit is equipped with a Power Failure Detector function included in the CPU which checks for an abnormal condition in the chassis power supplies. If, while the power is on, a failure is caused by any of the following that results in a low voltage supply, the CPU will turn the unit off in 1.5 seconds to prevent further damage:
# Failure within the power supply circuits.
# A short circuit in the load side from the supply.
Power Failure: Detected voltage failure for circuit. (Connected to IC800 pin 48 and pin 23.)
(Normal: High; Failure: Low)
If, while the power is off, the power is switched on and any of these failures remains uncorrected, the CPU will shut off the power within three seconds.
Check the following if the unit is turned off by the power
failure detector.
1. Disconnect the AC power cord (120V AC line) for a short time.
2. Connect a DC Voltmeter to the circuits shown below.
3. Press the Power key and check for the proper voltage supplies.
4. If any of these voltages is low, the power failure detector should turn the unit off within three seconds.
5. Check all circuits shown below.
Note: If power failure is detected 3 times in 15 minutes, the set will enter the standby mode and cannot be
switched On.To reset the operating programs of the CPU it is necessary to disconnect the AC cord for a short time
USB Software updated
(1) Insert the USB with the firmware which the file name is matched with the model name in factory mode.
(2) If system detects the same firmware file name, USB upgrade message would appear automatically.
(3) Press Left key to select “Yes”, and then press OK key to start the upgrading.
(4) Upgrading is starting, please wait for the progress finish.
(5) When the progress completed, please follow the instruction to remove USB and restart by AC off then on.
POWER SUPPLY CIRCUIT 
CLICK ON THE IMAGE TO ZOOM IN 

DPS-220AP-4A 1AV4U20C48900
CLICK ON THE IMAGE TO ZOOM IN