SHARP LC-26LE320 SOFTWARE UPDATE SERVICE MODE POWER SUPPLY AND LED DRIVER SCHEMATIC

SHARP BLU RAY

SHARP LC-26LE320 

LED TV


SOFTWARE UPDATE SERVICE MODE POWER SUPPLY AND LED DRIVER SCHEMATIC 

SOFTWARE UPGRADE PROCEDURE
1. Copy the firmware from your computer to the USB flash drives.
2.Change firmware name to upgrade.pkg
3.AC ON
4.Plug the USB flash drives into the USB port (service port) on the side I/O port of TV.
5.DC ON You can use Keypad or Remote control power key
6.When display Upgrade MENU ,select “Yes” by remote control to implement update firmware
7.When finished upgrade 100%,Please remove the USB flash drives then press “Power” to renew the TV
8.Press “MENU”+1999 to enter factory Menu by remote control. Then select “2.Main MCU Ver” to check upgrade firmware Version.
9.Implement “Exit” Icon to exit factory Menu . After exit factory mode, pls power off then turn off the AC power. congratulation, upgrade step is finish.
SERVICE MODE
Enter factory mode menu: 
press MENU + Numeric keys “1999” to enter factory mode.
Display adjustment
YPbPr Mode display adjustment
1 Auto color for signal slicering
General set-up
Equipment Requirements:
Knoica Minolta CS-200 or equivalent instrument. Quantum Data Pattern Generator 881 or equivalent instrument. Input requirements:
Input signal type: YPbPr signal
1. 1080i/25mode, TVBar100 pattern by QuantumData 881.
2. Select Picture mode to “Personal” mode and adjust the x, y data.
Input Signal Strength: 1 Vpp for Y signal ; 700 mVpp for Pb & Pr signal
Input Injection Point: YPbPr (RAC jack)
1080i/25, TVBar100 pattern
Alignment method:
Initial Set-up:
1. Select source as “YPbPr”.
2. Set Smart Picture mode as “Personal” and then adjust Contrast = 58, Brightness=48, Color=58, set Color Temp. to be “cool” mode.
3. Apply “TVBar100” pattern which is color bar pattern by signal generator.
4. Enter “factory mode menu”: press MENU + Numeric keys “1999”
Alignment:
1. At factory mode menu, select AUTO_COLOR item. Then press “OK” key of remote control to adjust ADC_GAIN_R, ADC_GAIN_G,
ADC_GAIN_B and ADC_OFFSET_R, ADC_OFFSET_G, ADC_OFFSET_B. Then store those values to NVM.
2. Check the 16 grayscale pattern should be distinguished and color bar is correct
3. Reset AV setting, picture mode shall be recalled to be “Vivid” and Contrast=58, Brightness=48; Color=58.
Sharp EU 2k10 models have no need to operate “AUTO_COLOR” function, due to EFUSE is set “Disable” within NVM for defult. These ADC values will
be produced by Main chip (MT5363) interal defination.
White balance adjustment
Alignment method:
Initial Set-up:
1. Select source as “YPbPr”.
2. Set Contrast = 58 and Brightness=48, Color=58, at normal menu mode.
3. Apply “80% white pattern or Flat 80 pattern by Component video generator.
4. Enter factory mode menu: press MENU + Numeric keys 1999”.
Alignment:
1. Apply Flat80 pattern (80% white pattern).
2. Set color temperature to “NORMAL”.
3. At factory mode menu, adjust the Scaler R Gain, Scaler G Gain, Scaler B Gain values to meet “NORMAL” color coordinates specification. Then store those values to NVM
4. Set color temperature to “COOL”.
5. At factory mode menu, adjust the Scaler R Gain, Scaler G Gain, Scaler B Gain values to meet “COOL” color coordinates specification below.
Then store those values to NVM
6. Set color temperature to “WARM”.
7. At factory mode menu, adjust the Scaler R Gain, Scaler G Gain, Scaler B Gain values to meet “WARM” color coordinates specification
. Then store those values to NVM
Color temperature Normal/Warm/Cool (x, y) co-ordinates specification:
Note:
1. Use Knoica Minolta CS-200 for color coordinates and luminance check.
2. For suitable mass production at factory, colour analyzers CA-210 can be applied. But, befor measureing ,all CA-210 should be coordinates and proofread with a Charoma Meter (CS-200) or equivalent instrument and a reference TV set.
3. Check the luminance at the center of the screen with 100% White. And to set Brightness control at 100; Contrast control at 100. Luminance
 > 200cd/m2 (Typ.) [ For LC-19LE320E/RU only at color temp.- *warm mode ]
> 200 cd/m2 (Typ.) [ For LC-22LE320E/RU only at color temp.- *warm mode ]
> 400 cd/m2 (Typ.) [ For LC-262LE320E/RU only at color temp.- cool mode ]
> 450 cd/m2 (Typ.) [ For LC-32LE320E/RU only at color temp.- cool mode ]
> TBD cd/m2 (Typ.) [ For LC-37LE320E/RU only at color temp.- cool mode ]
> TBD cd/m2 (Typ.) [ For LC-42LE320E/RU only at color temp.- cool mode ]
4. The defult values of Scaler R Gain, Scaler G Gain, Scaler B Gain are all 128. When panel WD is made adjustment, the three values could not be over 128. That is preventing color saturation after adjusting Contrast and Brithness setting at main menu.
PC mode display adjustment
1. Display quality adjustment
Use timing mode as describe in 2.2, and use the POPO (pixel on pixel off) pattern to adjust the clock until no stripe and adjust the phase until clear picture.(“Auto” will be done every time switching to PC mode and mode change) Check all preset 7 modes.
2. Auto color for signal slicering (B)
 General set-up
Equipment Requirements:
Knoica Minolta CS-200 or Equivalent Color analyzer. Chroma 2250 or equivalent PC signal generator.
Input requirements:
Input Signal Type:
PC VGA signal
1. 1024X7684/60Hz PC mode with ”5 white block” pattern. (see pattern-1)
Input Signal Strength:
0.7 Vp-p linear voltage.
Input Injection Point:
PC D-SUB input
Alignment method:
Initial Set-up:
1. Select source as “PC”.
2. Set Contrast = 58 (Sharp) and Brightness=100 (Sharp) , at normal menu mode.
3. Apply “5 white block”(pattern-1) pattern by VGA pattern generator.
4. Enter factory mode menu: press MENU + Numeric keys “1999” (factory mode menu).
Alignment:
At factory mode menu, select AUTO_COLOR item. Then press “OK” key to adjust ADC_GAIN_R, ADC_GAIN_G, ADC_GAIN_B and ADC_OFFSET_R, ADC_OFFSET_G, ADC_OFFSET_B. Then store those values to NVM.
Set Contrast = 100 (Sharp) and Brightness=100 (Sharp) Check color temperature specification with PC mode.
Note:
1. Use Knoica Minolta CS-200. for color coordinates and luminance check.
2. For suitable mass production at factory, colour analyzers CA-210 can be applied. But, befor measureing ,all CA-210 should be coordinates and proofread with a Charoma Meter (CS-200) or equivalent instrument and a reference TV set.
3. Check the luminance in the center of the screen with 100% White. And to Brightness control at 100; Contrast control at 100 Luminance
 > 200 cd/m2 (Typ.) [ For LC-19LE320E/RU only at color temp.- *warm mode ]
> 200 cd/m2 (Typ.) [ For LC-22LE320E/RU only at color temp.-*warm mode ]
> 360 cd/m2 (Typ.) [ For LC-26LE320E/RU only at color temp.- cool mode ]
> 360 cd/m2 (Typ.) [ For LC-32LE320E/RU only at color temp.- cool mode ]
> 360 cd/m2 (Typ.) [ For LC-37LE320E/RU only at color temp.- cool mode ]
> 360 cd/m2 (Typ.) [ For LC-42LE320E/RU only at color temp.- cool mode ]
POWER SUPPLY CIRCUIT 


LED DRIVER CIRCUIT
CLICK ON THE IMAGES TO ZOOM IN