CANON iR3300
Error codes
E000-0000
The reading of the main thermistor does not reach 30C 1
sec after the main power switch is turned on. Or, it does not reach 70C 2 sec
thereafter
The fixing film unit is faulty. The main thermistor has
an open circuit. The fixing heater has an open circuit. The main power supply
PCB is faulty. The DC controller PCB is faulty. To reset the error, execute the
following in service mode: COPIER>FUNCTION>CLEAR>ERR
1. Connector Is the connector of the fixing assembly
connected? a. main power supply PCB (J8) <-> relay connector <->
heater b. DC controller PCB (J320) <-> relay connector <->
thermistor NO: Connect the connector.
2. Fixing film unit (thermistor) Check the interval
between pin 1 and pin 2 and between pin 3 and pin 4 of the connectosr (4-pin)
of the thermistor for electrical continuity. Is it W (open)? YES: The heater
has an open circuit, or the thermal switch is open. Replace the fixing film unit.
3. Main power supply PCB, DC controller PCB Press the
Start key. Is the drive voltage of the heater supplied by the connector J8 of
the main power supply PCB? Main heater: between J8-1 (FSR1) and J8-5 (FSR COM)
Sub heater: between J8-3 (FSR2) and J8-5 (FSR COM) YES: The heater drive power
supply is faulty. Replace the main power supply PCB. NO: The thermistor control
mechanism is faulty. Replace the DC controller PCB.
E001-0000
The main thermistor detects 250C or higher
The fixing film unit is faulty (i.e., the thermistor has
a short circuit). The main power supply PCB is faulty. The DC controller PCB is
faulty. Caution To clear the error, execute the following in service move:
COPIER>FUNCTION>CLEAR>ERR.
1.Check the interval between pin 1 and pin 2 and between
pin 3 and pin 4 of the connectors (4-pin) of the thermistor for electrical
continuity. Is it 0 W (short circuit)? YES: The thermistor has a short circuit.
Replace the fixing film unit. If the thermistor has a short circuit, the
indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows
from the start: FIXC= 250°C for the main thermistor; FIX-E=310°C for the sub
thermistor.
2. Main power supply PCB, DC controller PCB Try replacing the main
power supply PCB. Is the problem corrected? YES: End. NO: Replace the DC
controller PCB.
E001-0001
The main thermistor or the sub thermistor detects
overheating (hardware circuit detection)
The fixing film unit is faulty (i.e., the thermistor has
a short circuit). The main power supply PCB is faulty. The DC controller PCB is
faulty. Caution To clear the error, execute the following in service move:
COPIER>FUNCTION>CLEAR>ERR
1.Check the interval between pin 1 and pin 2 and between
pin 3 and pin 4 of the connectors (4-pin) of the thermistor for electrical
continuity. Is it 0 W (short circuit)? YES: The thermistor has a short circuit.
Replace the fixing film unit. If the thermistor has a short circuit, the
indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows
from the start: FIXC= 250°C for the main thermistor; FIX-E=310°C for the sub
thermistor.
2. Main power supply PCB, DC controller PCB Try replacing the main
power supply PCB. Is the problem corrected? YES: End. NO: Replace the DC
controller PCB.
E001-0002
The sub thermistor detects about 295C or higher
The fixing film unit is faulty (i.e., the thermistor has
a short circuit). The main power supply PCB is faulty. The DC controller PCB is
faulty. Caution To clear the error, execute the following in service move:
COPIER>FUNCTION>CLEAR>ERR.
1.Check the interval between pin 1 and pin 2 and between
pin 3 and pin 4 of the connectors (4-pin) of the thermistor for electrical
continuity. Is it 0 W (short circuit)? YES: The thermistor has a short circuit.
Replace the fixing film unit. If the thermistor has a short circuit, the
indication in service mode (COPIER>DISPLAY>ANALOG) will be as follows
from the start: FIXC= 250°C for the main thermistor; FIX-E=310°C for the sub
thermistor.
2. Main power supply PCB, DC controller PCB Try replacing the main
power supply PCB. Is the problem corrected? YES: End. NO: Replace the DC
controller PCB.
E002-0000
The temperature of the fixing film is as follows: has
exceeded 100C, but does not reach 115C within 1 sec thereafter. has exceeded
140C, but does not reach 150C within 1 sec thereafter. has exceeded 160C, but
does not reach 165C within 1 sec thereafter
The fixing film unit is faulty (i.e., the main thermistor
TH1 has poor contact, or the fixing heater is faulty). The main power supply
PCB is faulty. The DC controller PCB is faulty. Caution To clear the error,
execute the following in service mode: COPIER>FUNCTION>FCLEAR>ERR.
1. State Turn on the power switch, and clear E002/E003.
Thereafter, turn off and then on the power switch. Does the fixing heater operate?
NO: See “The fixing heater fails to operate.”
2. Wiring Is the wiring from the DC controller PCB to the
fixing film unit normal? NO: Correct the wiring.
3. Fixing film unit, DC controller PCB Try replacing the
fixing film unit. Is the problem corrected? YES: End. NO: Replace the DC
controller PCB.
E003-0000
The main thermistor reading is lower than 140C when paper
is moved
The fixing film unit is faulty (i.e., the main thermistor
(TH1) has poor contact or has an open circuit; or, the fixing heater is
faulty). The main power supply PCB is faulty. The DC controller PCB is faulty.
Caution To clear the error, execute the following in service mode:
COPIER>FUNCTION>CLEAR>ERR
1. State Turn on the power switch, and clear E002/E003.
Thereafter, turn off and then on the power switch. Does the fixing heater
operate? NO: See “The fixing heater fails to operate.”
2. Wiring Is the wiring from the DC controller PCB to the
fixing film unit normal? NO: Correct the wiring.
3. Fixing film unit, DC controller PCB Try replacing the
fixing film unit. Is the problem corrected? YES: End. NO: Replace the DC
controller PCB.
E003-0001
An error in the rotation of the fixing film is detected. The
reading of the main thermistor is 100C or higher and, in addition, the fixing
film sensor does not detect the rotation of the film for 6 sec or more while
the fixing motor is driven
The fixing film sensor (PS45) is faulty. The DC
controller PCB is faulty. Caution To clear the error, execute the following in
service mode: COPIER>FUNCTION>CLEAR>ERR
1. Wiring Are the wring and the connectors connected
securely? DC controller PCB (J311) <-> relay connector <-> fixing
film sensor NO: Connect the wiring and the connectors.
2. Fixing film sensor Check the fixing film rotation
signal.When the fixing motor is rotating, is the film rotation detection signal
sent by the fixing film sensor to the concoctor J311 of the DC controller PCB?
Film rotation detection signal: 5V pulse signal between J311-A9 (FILM_ROT_D)
and J311-A8 (GND); at intervals of 100 msec ON and 440 msec OFF NO: If the
fixing film is normal, replace the sensor.
3. Fixing film unit, DC controller PCB Is there a fault
in the fixing film edge rotation detection mechanism? YES: Replace the fixing
film unit. NO: Replace the DC controller PCB.
E010-0000
After the main motor drive signal is generated, the clock
signal does to arrive within 1.3 sec
The main motor (M2) is faulty. the DC controller PCB is
faulty.
1. Connector Is the connector of the main motor
connected? NO: Connect the connector.
2. Main power supply PCB Is the drive voltage (24 V) of
the main motor supplied by the main power supply PCB? Main power supply PCB:
between J202-1 (24VU1-SW) and J202-2 (OVU1) NO: Replace the main power supply
PCB.
3. Main controller (M2), DC controller PCB Press the
Start key. Is the lock signal of the main motor present at the connector J308
on the DC controller PCB? Lock signal: J318-A10 (MM_LOCK) YES: Replace the main
motor. NO: Check the wiring; if normal, replace the DC controller PCB.
E014-000
After the fixing motor drive signal is generated, the
clock signal does not arrive within 1.3 sec.
The fixing motor (M19) is faulty. The DC controller PCB
is faulty.
1. Connector Is the connector of the fixing motor
connected? NO: Connect the connector.
2. Main power supply PCB Is the drive voltage (24 V) of
the fixing motor supplied by the main power supply PCB? Main power supply PCB:
between J202-3 (24VU1-S) and J202-4 (OVU1) NO: Replace the main power supply
PCB.
3. Fixing motor (M19), DC controller PCB Press the Start
key. Is the lock signal of the fixing motor present at the connector (J312) on
the DC controller PCB? Lock signal: J312-B4 (FSRM_LOCK*) the DC controller PCB
change from 0 to about 5 V? YES: Replace the fixing motor. NO: Replace the DC
controller PCB.