JVC LT-42DP8BG SERVICE MODE AND POWER SUPPLY SCHMATICS - USING MIP20MSSCF – FAN5500AN

JVC LT-42DP8BG

HOW TO RESET THE OPERATING TIME
(1) Press the [MENU] key simultaneously, then enter the USER MENU.
(2) Select the "Features" from the USER MENU.
(3) Select the Blue back from the Features.
(4) Set the Blue back to Off.
(5) Press the [INFORMATION] key and [MUTING] key simultaneously, then enter the SERVICE MODE.
(6) When the Main Menu is displayed, press [2] key to enter the self check mode.
(7) When the self check screen is displayed, press [ZOOM] key.
(8) "RESET : OK" is displayed under the operating time.
(9) Press the [TV] key to reset the operating time.
NOTE:
When the LCD PANEL UNIT is replaced, be sure to reset the operating time following the above method.
SYSTEM SETTING
1) Press the [INFORMATION] key and [MUTING] key simultaneously, then enter the SERVICE MODE.
(2) When the Main Menu is displayed, press [2] key to enter the self check mode.
(3) Turn off the power by pressing the [POWER] key on the remote control unit.
ADJUSTMENT MODE
This mode is used to adjust the VIDEO CIRCUIT and the MTS CIRCUIT.
HOW TO ENTER THE ADJUSTMENT MODE
When the SERVICE MENU SCREEN of SERVICE MODE is displayed, press [1] key to enter the ADJUSTMENT MODE.
WHITE BALANCE (HIGHLIGHT)
(1) Receive a PAL 75% all white signal.
(2) Set PICTURE MODE to "STANDARD".
(3) Set ZOOM to "FULL".
(4) Set COLOUR TEMP. to "NORMAL".
(5) Select "1.ADJUST" from the SERVICE MODE.
(6) Adjust to Keep one of <S001> (Red drive), <S002> (Green drive) or <S003> (Blue drive) unchanged, then lower the other two so that the all-white screen is equally white throughout.
NOTE:
Set one or more of <S001>, <S002>, and <S003> to "137".
(7) Check that white balance is properly tracked from low light to high light. If the white balance tracking is deviated, adjust to correct it.
(8) Press the [MUTING] key to memorize the set value.
HOW TO ENTER THE SELF CHECK MODE
Before enter the SELF CHECK MODE, press the [MODE] key to confirm that "TV" position is indicated. If it is in a wrong position, the SELF CHECK MODE operation cannot be performed.
(1) Press the [INFORMATION] key and [MUTING] key simultaneously, then enter the SERVICE MODE.
(2) Press the [2] key SELF CHECK MODE.
(3) Press the [RED] key to enter Page 2 of the SELF CHECK MODE.
*Use the [GREEN] key to toggle between Page 1 and Page 2.
NOTE:
When a number key other than the [2] key is pressed in the SERVICE MODE screen, the other relevant screen may be displayed.
This is not used in the SELF CHECK MODE. Press the [MENU] key to return to the MAIN MENU SCREEN.
HOW TO EXIT THE SELF CHECK MODE
To Save Failure History:
Turn off the power by unplugging the AC power cord plug when in the Self check display mode.
To Clear (Reset) Failure History:
Turn off the power by pressing the [POWER] key on the remote control unit when in the Self check display mode.
POINTS TO NOTE WHEN USING THE SELF CHECK FEATURE
In addition to circuit failures (abnormal operation), the following cases may also be diagnosed as "Abnormal" and counted.
(1) Temporary defective transmissions across circuits due to pulse interruptions.
(2) Misalignment in the on/off timing of power for I2C bus (Vcc) when turning on/off the main power.
Therefore, turn on the main power, and then wait for about 3 seconds before starting Self check. If recurrences are expected, ensure to clear (reset) the failure history and record the new diagnosis results.
POWER SUPPLY SCHEMATICS 
USING MIP20MSSCF – FAN5500AN