PANASONIC HC-V10 - HC-V11 Digital Video Camera SERVICE MODE AND FACTRORY RESETING

PANASONIC HC-V10 - HC-V11

Service Mode
1. Indication method of the service menu
Set the mode switch “Recording” mode.
2. Turn the power on, and then while keep pressing the “Zoom lever” to W side, “Intelligent auto/Manual” button and “Menu” button for more than 3 seconds until the top screen of the Service Mode Menu being displayed.
Lock search history indication
• Display the camera system error cord for three histories saved in EEPROM
• The error cord contents which are displayed
Error code
Function
51
Focus control is abnormal
52
Zoom control is abnormal
53
OIS lens control is abnormal

Service mode menu
Factory settings
Function to throw a product up in a factory shipment state (Even if recorded data exists in the build-in memory, factory settings perform the initialization of build-in memory and clear the history data.)
3. End method of the top screen of the service mode menu
Press the [MENU] button to end the service mode, and then POWER OFF.
History Display
Press the “[UP] or [DOWN] of cursor” button for the item No. [4] is yellow high lighted, then press “ENTER” button to display the unit histories.
Indication contents
• Display the total operating time (in power on and EE state), total movie recording time and total number of photo taken. (They are stored in EEPROM).
Item
Contents
PWR
Total elapsed time
EE
Total working time of camera sensor
REC SD
Movie recorded time of inserted SD card
PICT SD
Picture recorded number of inserted SD card
REC ESD
Movie recorded time of internal memory
PICT ESD
Picture recorded number of internal memory

How To Turn On The Factory Settings?
(CAUTION)
Performing the factory settings, the built-in memory is initialized and all of recorded data are deleted. (SD memory card is not initialized by the factory settings.)
1. Set the mode switch “Recording” mode.
2. Turn the power on, and then while keep pressing the “Zoom lever” to W side, “Intelligent auto/Manual” button and “Menu” button for more than 3 seconds until the top screen of the Service Mode Menu being displayed.
3. Under the condition of the Item No. [ 1 ] is yellow high lighted , then press “ENTER” button.
4. By pressing the “[UP] or [DOWN] of cursor” button and display a highlight in a [ YES ] item, then press the “ENTER” button.
5. After few seconds “END” is displayed on LCD monitor. Press [ POWER ] button or cutting of battery connection or AC power
supply connection as a completion of the “FACTORY SETTINGS”.
NOTE:
Do not using service mode except above table of Service mode menu.
End method of the top screen of the service mode menu.
Push the “MENU” button to end the service mode, and then POWER OFF.
The Factory Settings?
The factory settings clean up and/or refresh the following settings.
1. Physical formatting of the built-in memory. (All user recorded data are deleted)
2. MENU, MODE, ADJUSTMENT VALUE.
3. Reset the folder number and file number of still pictures. (Setting the folder number is 100, and file number is 0.)
4. Clear the service mode information contents.
5. Initialize the VIERA Link Physical Address.
When Replacing the Main P.C.B.
After replacing the MAIN P.C.B., be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-AVC” web-site in
“TSN system”, together with Maintenance software.