SONY BDP-CX7000ES SERVICE MODE AND ADJUSTMENTS - 400 BLURAY CHANGER

SONY BDP-CX7000ES

 400 BLURAY CHANGER 

BD SERVICE MODE
Note: The operation in this mode must use a remote commander.
Setting method of the BD service mode:
1. It is confirmed that the AC power cord is pulled out.
2. Press the [STOP], [OPEN/CLOSE] and [DISC EJECT] buttons, next the AC power cord is inserted.
3. The message “SERVICE MODE” appears on the fluorescent indicator tube and enter the BD service mode (it keeps pressing the buttons
until the message is displayed).
Menu composition
1. Diag (test function)
2. Log (log display)
3. Factory Initialize (returns to the state of the factory shipment)
4. Ship Mode (ship mode setting and power off)
5. Network (network information display)
6. System Information (system information display)
Service Mode Menu (Top Menu)
This is the top menu of service mode.
Each function is accessed from this screen.
Operation:
[1] Moves to Diag screen.
[2] Moves to Log screen.
[3] Moves to Factory Initialize screen.
[4] Moves to Ship Mode screen.
[5] Moves to Network screen.
[6] Moves to System Information screen.
[UP]/[DOWN] Moves the cursor.
[3] Moves to the screen of the item selected with the cursor.
* Cursor is not displayed when the menu is first displayed.
Factory Initialize
Data base, remote control mode, password and other setting value are initialized, Gracenote relation file is deleted.
Operation:
Press the [ENTER] button in this screen when restoring the set to its factory settings.
[ENTER] Initialize the set to its factory settings.
[RETURN] Return to the top menu of the service mode.
Changer Mecha Test (Changer Mecha Test)
Mechanism cannot be operated if it does not initialize it when the message of “Initialize first, please.” is displayed.
The message of “Initialize first, please.” disappears when initialization is done.
The sensor display is always updated.
DISC Sensor: “0” or “1” is displayed.
TABLE Sensor: “0” or “1” is displayed.
LOAD Sensor: The state is displayed (“Released”, “Release <>Lock”, “Table Locked” or “Chucked”).
DOOR Sensor: The state is displayed (“Opened”, “Moving”, “Closed”, “Opened/Popper Up”, “Opened/Popper
Moving” or “Opened/Popper Down”).
Mechanism can be operated by pressing the button of the corresponding remote commander.
[0] The initialization of mechanism is executed.
[1] The door opens and pop up when the door closes. The pop up when the door opens and not pop up. The pop down when the door opens and pop up.
[OPEN/CLOSE] The door is opened or closed.
[PREV] One slot is rotated to the left (when the door closes, it opens) (when the chucking, it chuck down).
[NEXT] One slot is rotated to the right (when the door closes, it opens) (when the chucking, it chuck down).
[REW] One rotation to the left (when the door closes, it opens) (when the chucking, it chuck down).
[FWD] One rotation to the right (when the door closes, it opens) (when the chucking, it chuck down).
[PLAY] Disc at the position of the drive is downed in the chuck or the chucking.
Ship Mode
Changer Mechanism is changed to the ship mode. Eject all disc in the table before it enters this mode.
Operation:
Press the [ENTER] button in this screen when setting the chucking down, turn table free and door closed, and turn the power off. [ENTER] Changes to the ship mode. [RETURN] Return to the top menu of the service mode
POP UP MECHANISM ADJUSTMENT
Procedure:
1. Press the [PLAY] button, The message “TABLE_ADJUST *” is appears on the fluorescent indicator tube, and entering table adjust mode.
2. The cover chassis is removed, and the screw is loosened (the screw is not detached)
3. The door is moved by the hand, and it puts it into the state that there is no lever in the hole of the table.
4. The hole and the lever of the table are matched to the center (it shines on with the spotlight etc. and confirm it).
5. It is confirmed that there is a lever in the position of the guideline under the table because it does not match it to the adjoining slot.
6. The door is moved by the hand, it is confirmed that the lever rises to the center of the hole of the table.
7. The screw of step 3 is fixed (it is noted to tighten strongly and not to destroy it), and the cover chassis is installed.