AV RECEIVER
3D READY
PIONEER VSX-1022-K - VSX-42 -VSX-822-K
SERVICE MODE SOFTWARE UPDATE IDLE CURRENT SETTING AND POWER AMP CIRCUIT
SERVICE MODE
Purpose
The numbers of detections for various protection processes are displayed.
The numbers of detections for various protection processes are displayed.
How to enter/exit
During Standby mode, simultaneously press and hold the [PRESET LEFT ] and [STANDBY/ON] keys for 2 seconds to enter this mode.
The display will return to the normal indication when no key operation is performed for 5 seconds.
During Standby mode, simultaneously press and hold the [PRESET LEFT ] and [STANDBY/ON] keys for 2 seconds to enter this mode.
The display will return to the normal indication when no key operation is performed for 5 seconds.
Reset mode for numbers of protection detections
Purpose
For clearing all the counts of protection detections.
(This mode resets the counts of protection detections.)
For clearing all the counts of protection detections.
(This mode resets the counts of protection detections.)
How to enter/exit
During Standby mode, simultaneously press and hold the [ALC/STANDARD SURR] and [STANDBY/ON] keys for 10 seconds to enter this mode.
The display will return to the normal indication when no key operation is performed for 5 seconds.
During Standby mode, simultaneously press and hold the [ALC/STANDARD SURR] and [STANDBY/ON] keys for 10 seconds to enter this mode.
The display will return to the normal indication when no key operation is performed for 5 seconds.
Detailed explanations
1. When the procedures for Reset mode for numbers of
protection detections are completed, all the counters will be reset to
"000."
2. Prohibitions:
The protection detection counts cannot be cleared (reset to 000) with the MEMORY CLEAR process. They can only be cleared when the procedures of Reset mode are completed.
Notes on Ground Points Connection
2. Prohibitions:
The protection detection counts cannot be cleared (reset to 000) with the MEMORY CLEAR process. They can only be cleared when the procedures of Reset mode are completed.
Notes on Ground Points Connection
During repair, before checking the MAIN Assy, etc., with the
rear chassis removed, be sure to connect the GND terminal of the main capacitor
to the back chassis (speaker chassis), as shown below, then connect the power
cord.
Without grounding connection, the protection
circuit will be activated. After repairing, be sure to remove the
ground wire before reassembling.
UPDATING OF THE FIRMWARE
Purpose
Refer to this section when updating the firmware of each microcomputer is required by the service information, etc.
Refer to this section when updating the firmware of each microcomputer is required by the service information, etc.
Necessary Tools and Connections
# PC with a serial port
# RS-232C cable (9-pin to 9-pin, straight cable) (Marketing product)
# UPDATE jig: GGF1642 (Use FFC of GGF1642. (10P to 10P FFC))
# Firmware
MAIN microcomputer firmware update
# PC with a serial port
# RS-232C cable (9-pin to 9-pin, straight cable) (Marketing product)
# UPDATE jig: GGF1642 (Use FFC of GGF1642. (10P to 10P FFC))
# Firmware
MAIN microcomputer firmware update
Preestablishment
# NetworkStandby: OFF
# HDMI Control: OFF
# HDMI StandbyThrough: OFF (North America model only)
# NetworkStandby: OFF
# HDMI Control: OFF
# HDMI StandbyThrough: OFF (North America model only)
Procedures
1. Unplug the AC cord. Connect the FFC cable. ( MAIN microcomputer ) Start up application FlashSta on the PC.2. Plug the AC cord. (STANDBY mode) For updating of the MAIN microcomputer, proceed with the following steps in STANDBY mode.
1. Unplug the AC cord. Connect the FFC cable. ( MAIN microcomputer ) Start up application FlashSta on the PC.2. Plug the AC cord. (STANDBY mode) For updating of the MAIN microcomputer, proceed with the following steps in STANDBY mode.
3. Press the OK button.
IF TIME OUT DISPLAYED
Please push the cancel button and press the JIG's RESET
button.
And confirm a connection of FFC. Please return to procedure 1
And confirm a connection of FFC. Please return to procedure 1
4. Select the update file and enter ID.
a. Selection of upgrade file
b. Select the update file
b. Select the update file
Select "VSX_1022Mid_Main Ver***.mot" or
"VSX42_Main_Ver0.60.mot" "VSX_822Mid_Main Ver***.mot" file
to update the MCU.
c. Enter ID
Press the OK button.
5. Set speed update and update the MCU.
a. Set speed of update.
b.Set Baud rate to 38400.
c.Update the MCU. E.P.R=>Erase+Program+Read . Update the
MCU Press the E.P.R … button
Press OK button.
6. Update Finished MAIN microcomputer.
Press the OK button.
Press the Exit
button. Please wait for until this window disappears.
IF TIME OUT DISPLAYED
Push the JIG’s RESET button during 1 sec.
Press the OK button.
Press the OK button.
Select the 9600 of the Board rate then press the OK button
7. Unplug the AC cord. Disconnect the FFC cable
SUB microcomputer firmware update
Preparations
Save the firmware file to the "root" of empty USB memory.
The file name of the firmware file is "RegM13Sub_V***.bcd". Don't save other files.
Save the firmware file to the "root" of empty USB memory.
The file name of the firmware file is "RegM13Sub_V***.bcd". Don't save other files.
# NetworkStandby: OFF
# HDMI Control: OFF
# HDMI StandbyThrough: OFF (North America model only)
# Connect a unit to TV and HDMI, and the GUI output of the unit performs in a state to appear.
# HDMI Control: OFF
# HDMI StandbyThrough: OFF (North America model only)
# Connect a unit to TV and HDMI, and the GUI output of the unit performs in a state to appear.
Procedures
1. Turn on the unit.
2. Set a function for a "NETRADIO".
Note:
Without a network connection, "Server Error" will be displayed on the TV screen. Under this condition, the Service Menu (menu for updating the SUB microcomputer) is not accessible. Set the remote control unit supplied with the unit to Network Function Operation mode then press the ENTER button so that "Empty" is displayed on the screen. Then proceed to Step 3.
(2) When a product cannot recognize a file, FILE NOT FOUND. Check on USB memory with a file.
1. Turn on the unit.
2. Set a function for a "NETRADIO".
Note:
Without a network connection, "Server Error" will be displayed on the TV screen. Under this condition, the Service Menu (menu for updating the SUB microcomputer) is not accessible. Set the remote control unit supplied with the unit to Network Function Operation mode then press the ENTER button so that "Empty" is displayed on the screen. Then proceed to Step 3.
(2) When a product cannot recognize a file, FILE NOT FOUND. Check on USB memory with a file.
3. Press the "ESC (A85F)" button on the Service
remote control unit (GGF1381), then press the "+10 (A81F)" button to
enter the service menu (for SUB microcomputer firmware update menu).
When you press other buttons between "ESC" button and "+10" buttons, be invalid.
When you press other buttons between "ESC" button and "+10" buttons, be invalid.
4. Press the "ENTER" button of the remote control
unit supplied with Network Function as the state that you can operate.
(1) When a product can recognize a file, become the following indication.
Select "Start", and press the "ENTER" button.
(1) When a product can recognize a file, become the following indication.
Select "Start", and press the "ENTER" button.
5. Update starts, and "UPDATE" blinks to FL screen
and HDMI LED blinks. Be approximately 8 minutes for update at time.
6. When update is completed, "Completed" is
displayed by TV screen and HDMI LED lights.
* "UPDATE" blinks to FL display and is displayed.
In rare cases, "Completed!" may not be displayed on th TV screen. In such a case, updating is completed if the HDMI LED has become lit. Proceed to Step 7.
* "UPDATE" blinks to FL display and is displayed.
In rare cases, "Completed!" may not be displayed on th TV screen. In such a case, updating is completed if the HDMI LED has become lit. Proceed to Step 7.
7. Disconect the AC power cord. (The POWER button does not
respond.) Confirm a version of the firm ware of SUB microcomputer.
Note:
Because update is not possible again, never unplug the power cord until the updating process is completed.
Note:
Because update is not possible again, never unplug the power cord until the updating process is completed.
USB (BridgeCo) firmware update
Procedures
1. Select ‘Firmware Update’ from the Network Setup menu. The receiver checks whether the USB memory device inserted into the USB port on the receiver’s front panel contains updatable software.
2. To update, select ‘Start’.
3. When ‘Updating in progress, don’t unplug!’ is displayed, select ‘OK’.
# If ‘File Not Found’ is displayed, try the following:
No update file was found on the USB memory device. Store the file in the USB memory device’s root directory.
Try disconnecting then reconnecting the USB device or storing the update file again. If the error still occurs, try using
a different USB memory device.
4. The software update will start. Please wait. The OSD display will turn off during update and the words ‘UPDATE’ will flash on the front panel.
5. If ‘COMPLETE’ is displayed, updating is completed. The screen will return automatically to the play screen.
# If ‘FAIL’ is displayed on the front panel display, updating has failed. Try the following:
Turn the receiver’s power off, then turn it back on and try updating the software again.
Try disconnecting then reconnecting the USB device or storing the update file again. If the error still occurs, try using a different USB memory device.
1. Select ‘Firmware Update’ from the Network Setup menu. The receiver checks whether the USB memory device inserted into the USB port on the receiver’s front panel contains updatable software.
2. To update, select ‘Start’.
3. When ‘Updating in progress, don’t unplug!’ is displayed, select ‘OK’.
# If ‘File Not Found’ is displayed, try the following:
No update file was found on the USB memory device. Store the file in the USB memory device’s root directory.
Try disconnecting then reconnecting the USB device or storing the update file again. If the error still occurs, try using
a different USB memory device.
4. The software update will start. Please wait. The OSD display will turn off during update and the words ‘UPDATE’ will flash on the front panel.
5. If ‘COMPLETE’ is displayed, updating is completed. The screen will return automatically to the play screen.
# If ‘FAIL’ is displayed on the front panel display, updating has failed. Try the following:
Turn the receiver’s power off, then turn it back on and try updating the software again.
Try disconnecting then reconnecting the USB device or storing the update file again. If the error still occurs, try using a different USB memory device.
DSP firmware update
Preestablishment
# NetworkStandby: OFF
# HDMI Control: OFF
# HDMI StandbyThrough: OFF (North America model only)
# NetworkStandby: OFF
# HDMI Control: OFF
# HDMI StandbyThrough: OFF (North America model only)
Procedures
1. Select an Input Function that allows reception via Optical input 1 then set the unit to STBY_Off mode.
2. Press the SPEAKERS and STANDBY/ON keys simultaneously to enter DSP UpDate mode. ("DSP UP" is displayed.)
3. When "PLAY" is displayed, playback of the .wav file starts. (Play the file only once. NEVER repeat playback.)
("PLAY" is displayed.)
4. After playback is finished and "ENTER" is displayed, press the ENTER key on the front panel. ("ENTER" is displayed.)
5. "WRITING" is automatically displayed.
6. After writing is completed, "COMPLETE" is displayed.
7. Turn the unit off then confirm that the version has been updated.
1. Select an Input Function that allows reception via Optical input 1 then set the unit to STBY_Off mode.
2. Press the SPEAKERS and STANDBY/ON keys simultaneously to enter DSP UpDate mode. ("DSP UP" is displayed.)
3. When "PLAY" is displayed, playback of the .wav file starts. (Play the file only once. NEVER repeat playback.)
("PLAY" is displayed.)
4. After playback is finished and "ENTER" is displayed, press the ENTER key on the front panel. ("ENTER" is displayed.)
5. "WRITING" is automatically displayed.
6. After writing is completed, "COMPLETE" is displayed.
7. Turn the unit off then confirm that the version has been updated.
IDLE CURRENT ADJUSTMENT
When any component parts which are within the red square on
the following circuit diagram are replaced, the idle current adjustment of that
channel is required. (Idle current adjustment for another channel is not
required.) However, when any capacitors are replaced, the adjustment is not
required. (The following circuit diagram is for SL channel, but another channel
also has same circuit diagram and same adjustment is required)
IDLE CURRENT ADJUSTMENT FOR VSX-1022-K, VSX-42
Channel
|
Measurement
Points
|
Adjustment Points
|
Procedure
|
FL
|
TP404 pin 1 (+) TP404 pin 3 (–) |
VR404
|
1. Turn
on the power.
2. Perform aging for one minute. 3. Connect a digital voltmeter to the measurement point. 4. Turn the adjustment VR so that the voltage becomes in 2.0 mV ± 0.2 mV. (Condition : No signal and no load) |
FR
|
TP402
pin 1 (+)
TP402 pin 3 (–) |
VR402
|
|
C
|
TP403
pin 1 (+)
TP403 pin 3 (–) |
VR403
|
|
SL
|
TP401
pin 1 (+)
TP401 pin 3 (–) |
VR401
|
|
SR
|
TP405
pin 1 (+)
TP405 pin 3 (–) |
VR405
|
|
SBL
|
TP406
pin 1 (+)
TP406 pin 3 (–) |
VR406
|
|
SBR
|
TP407
pin 1 (+)
TP407 pin 3 (–) |
VR407
|
IDLE CURRENT ADJUSTMENT FOR VSX-822-K
Channel
|
Measurement Points
|
Adjustment Points
|
Procedure
|
FL
|
TP401
pin 1 (+)
TP401 pin 3 (–) |
VR401
|
1. Turn
on the power.
2. Perform aging for one minute. 3. Connect a digital voltmeter to the measurement point. 4. Turn the adjustment VR so that the voltage becomes in 2.0 mV ± 0.2 mV. (Condition : No signal and no load) |
FR
|
TP402
pin 1 (+)
TP402 pin 3 (–) |
VR402
|
|
C
|
TP403
pin 1 (+)
TP403 pin 3 (–) |
VR403
|
|
SL
|
TP404
pin 1 (+)
TP404 pin 3 (–) |
VR404
|
|
SR
|
TP405
pin 1 (+)
TP405 pin 3 (–) |
VR405
|
POWER AMPLIFIER CIRCUIT
CLICK ON THE IMAGE TO ZOOM IN