SONY KDL-40V4100 - KDL-40V4100 - KDL-40V4150 SERVICE MODE AND POWER SUPPLY CIRCUIT

SONY KDL-40V4100 - KDL-40V4150


SERVICE MODE AND POWER SUPPLY CIRCUIT 

SELF-DIAGNOSTIC FUNCTION
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED indicator will automatically begin to fl ash. The number of times the LED fl ashes translates to a probable source of the problem. A definition of the STANDBY LED fl ash indicators is listed in the instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY LED indicator will fl ash a set number of times to indicate the possible cause of the problem. If there is more than one error, the indicator will identify the fi rst of the problem areas.
Viewing the Self Check Diagnostic List
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a second of each other:
DISPLAY > Channel 5 > Volume - > TV POWER .
The Self Check list displays. This differs from accessing Service Adjustments.
Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a “0”.
NOTE: If the Service Menu display text is not completely visible, press the Menu HOME button on the Remote Commander to refresh the display.
3. Press the Channel 1 button on the Remote Commander to go to Page 2 of the Self Check list.
4. Press the Channel 4 button on the Remote Commander to go back to Page 1 of the Self Check list.
5. To exit Self Check display, turn the power off.
Clearing the Self Check Diagnostic List
1. In Service Mode, press the Channel 8 Channel 0 .
ACCESSING SERVICE ADJUSTMENT MODE
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a
second of each other:
DISPLAY > Channel 5 > Volume + > POWER .
USING THE REMOTE COMMANDER TO VIEW SERVICE DATA
Use the buttons on the Remote Commander to access the service menu
items and adjust the data values.
1. Access Service Mode.
Press the following buttons on the Remote Commander within a second of each other:
DISPLAY > Channel 5 > Volume + > POWER .
The screen displays the fi rst category in the selected service menu.
NOTE: If the Service Menu display text is not completely visible, press the Menu HOME button on the Remote Commander to refresh the display.
2. To change the category, press 2 or 5 on the Remote Commander.
Note: Pressing 2 or 5 only changes the categories within the service menu displayed.
To change a category on one of the other service menus, press the JUMP button until the correct service menu is displayed.
3. To change the adjustment item, press 1 or 4 on the Remote Commander.
4. To exit service mode, turn the power off.
RESETTING TO FACTORY DEFAULTS
Use the following instructions to restore the User Controls and Channel Memory settings to the preset factory conditions.
1. While holding down the on the Remote Commander, press the POWER button on the Front Panel of the set. The set restarts and displays the initial setup screen. This may take several minutes.
POWER SUPPLY CIRCUIT 